manufacture Note for automatic sealing machine:
1. Each turn of the sealing carousel has 12 stations (that is, 12 equal parts). The splitter parameters, deceleration and parameters listed in the purchased parts list are for reference only, because they need to be determined according to the output per minute required by the user.
2. A certain amount of butter (molybdenum disulfide grease) is always kept in the gear box.
3. Refuel the buttermouth American class once.
4. There should be oil seals on both sides of each radial bearing (head of 6).
5. The round pin φ8 of the part number 24# should be pressed in, and then thin spring steel sheet z (thickness d = 0.5 ± 0.02 after surface grinder is used to adjust the gap between d = 0.03-0.05, and often Add oil and lubricate.
6. Before installing needle roller bearings and cylindrical roller bearings, lubricate each ring.
7. Part number 41# plane bearing should also be greased during use.
8. The shape and structure of the sealing roller and roller shaft are for reference only.
9. The material of the turntable is hard plastic in South Korea, bakelite or aluminum alloy plate is used in the world. One is not to attract magnetism, the other is to be easy to process and maintain accuracy, and the third is not to deform. Please choose reasonably.
10. For jars of different diameters, turntables and pressure heads with different positioning arcs are used.
11. The automation and coordination of electrical appliances, segmentation, indexing, and cylinder production are controlled by plc and designed by electrical engineers.
12. An additional conveyor belt without motor is used for emptying the tank at the inlet side, about 2mm long.
13. The guard and door can be made according to the base and referring to the video.
14. The part number 112# turntable dead-point electronic photoreceptor assembly, can be installed on the workbench below the turntable empty to install the induction photoelectric tube, or you can refer to this general drawing or video to make a seat installation, which is determined by the electrical engineer.
15. The upper and lower dead point sensor assembly of the pressure tank cylinder is replaced by an electromagnetic liver yin with the cylinder sda80*65, which electrical engineers know.